10 supplement, 1 technical data – VEGA VEGASON 64 Profibus PA User Manual

Page 49

Advertising
background image

10 Supplement

10.1 Technical data

General data

Materials, wetted parts

-

Flange

PP or Aluminium

-

Swivelling holder, flange

galvanized steel

-

Transducer

PA (1.4301 with StEx)

-

Transducer diaphragm

316Ti

Materials, non-wetted parts

-

Housing

Aluminium die-casting powder coated

-

Seal between housing and housing
cover

Silicone

-

Inspection window in housing cover

Polycarbonate (UL-746-C listed)

-

Ground terminal

316Ti

-

transducer cable with separate version C
and D

PUR (1.1082)

Weight

5)

-

Compact with flange (version A)

5.6 … 10.7 kg (12.3 … 23.6 lbs)

-

Compact with swivelling holder
(version B)

6.9 … 9.7 kg (15.2 … 21.4 lbs)

-

Separate with swivelling holder
(version C)

7.5 … 10.5 kg (16.5 … 23.1 lbs)

-

Separate with threaded fitting (version D)

4.7 … 6.9 kg (10.4 … 15.2 lbs)

Output variable

Output signal

digital output signal, format according to IEEE-754

Sensor address

126 (default setting)

Current value

10 mA, ±0.5 mA

Damping (63 % of the input variable)

0 … 999 s, adjustable

Step response or adjustment time

250 ms (ti: 0 s, 10 … 90 %)

Input variable

Measured value

-

Version A

distance between lower edge of the flange and
product surface

-

version B, C and D

distance between lower edge of the transducer and
product surface

5)

Depending on size and process fitting material.

VEGASON

64 • Profibus PA

49

10 Supplement

28787

-

EN

-081127