VEGA VEGASON 64 Profibus PA User Manual

Page 52

Advertising
background image

Ambient conditions

Ambient, storage and transport temperature

-40 … +80 °C (-40 … +176 °F)

Process conditions

Process pressure

-

Version A with PP flange

0 kPa

-

Other versions

-20 … 50 kPa/-0.2 … 0.5 bar (-2.9 … 7.3 psi)

Process temperature (transducer temper-
ature)

-40 … +80 °C (-40 … +176 °F)

Vibration resistance

mechanical vibration with 1 g in the frequency
range 5 … 200 Hz

9)

Electromechanical data

Cable entry

-

Double chamber housing

l

1 x cable gland M20 x 1.5 (cable: ø 5 … 9 mm),
1 x blind stopper M20 x 1.5; plug M12 x 1 for
VEGADIS

61 (optional)

or:

l

1 x closing cap ½ NPT, 1 x blind stopper
½ NPT

, plug M12 x 1 for VEGADIS 61

(optional)

or:

l

1 x plug (depending on the version), 1 x blind
stopper M20 x 1.5; plug M12 x 1 for VEGADIS
61 (optional)

Spring-loaded terminals for wire cross-sec-
tion up to

2.5 mm² (AWG 14)

Transducer cable

10)

-

Length

5 … 300 m (16.4 … 984.3 ft)

-

Diameter

7.2 … 7.6 mm (0.283 … 0.299 in)

Indicating and adjustment module

Voltage supply and data transmission

through the sensor

Indication

LC display in dot matrix

Adjustment elements

4 keys

Protection

-

unassembled

IP

20

-

mounted into the sensor without cover

IP

40

9)

Tested according to the regulations of German Lloyd, GL directive 1.

10)

With separate version C and D.

52

VEGASON

64 • Profibus PA

10 Supplement

28787

-EN

-081127

Advertising