2 principle of operation, 3 operation, 4 packaging, transport and storage – VEGA VEGAWELL 51 4 … 20 mA User Manual

Page 10

Advertising
background image

3

.2 Principle of operation

VEGAWELL

51

is used for level measurement in vessels and

for gauge measurement in deep wells, e.g. in water/sewage
water applications.

1)

T

he actual sensor element is the CERTEC

®

measuring cell

with rugged ceramic diaphragm. The hydrostatic pressure
causes a capacitance change in the measuring cell via the
ceramic diaphragm. This change is converted into an
appropriate output signal.

T

wo-wire electronics 4 … 20 mA for power supply and

measured value transmission on the same cable.

T

he supply voltage range can differ depending on the

instrument version.

D

ata for power supply are specified in chapter "Technical

data".

3

.3 Operation

VEGAWELL

51

with 4 … 20 mA electronics has no adjustment

option.

3

.4 Packaging, transport and storage

Y

our instrument was protected by packaging during transport.

I

ts capacity to handle normal loads during transport is assured

by a test according to DIN EN 24180.

T

he packaging of standard instruments consists of environ-

ment-friendly, recyclable cardboard. For special versions, PE
foam or PE foil is also used. Dispose of the packaging material
via specialised recycling companies.

T

ransport must be carried out under consideration of the notes

on the transport packaging. Nonobservance of these instruc-
tions can cause damage to the device.

T

he delivery must be checked for completeness and possible

transit damage immediately at receipt. Ascertained transit
damage or concealed defects must be appropriately dealt
with.

1)

F

or use in closed vessels under vacuum, VEGAWELL 51 is available with

absolute pressure measuring ranges.

Application range

Functional principle

Voltage supply

Packaging

Transport

Transport inspection

10

VEGAWELL

51 • 4 … 20

mA

P

roduct description

32465

-EN

-080604

Advertising