10 supplement, 1 technical data, 10 .1 technical data – VEGA VEGAPULS 67 (≥ 2.0.0 - ≤ 3.8) Foundation Fieldbus User Manual

Page 53

Advertising
background image

10

Supplement

10

.1 Technical data

General data

316L corresponds to 1.4404 or 1.4435

Materials, wetted parts

-

Horn antenna

PBT-GF30

-

Focussing lens

PP

-

Adapter flange

PPH

-

Seal, adapter flange

FKM (Viton)

Materials, non-wetted parts

-

Compression flange

PPH

-

Mounting strap, fixing screws mounting
strap

316L

-

Fixing screws, adapter flange

304

-

Housing

Plastic PBT (polyester), Alu die-casting powder-
coated, stainless steel 316L

-

Seal between housing and housing
cover

NBR (stainless steel housing), silicone (Alu/plastic
housing)

-

Inspection window in housing cover for
PLICSCOM

Polycarbonate (UL-746-C listed)

-

Ground terminal

316Ti/316L

Max. torque, mounting screws - strap on the
sensor housing

4 Nm (2.95 lbf ft)

Weight, depending on housing material and
version

0.7 … 3.4 kg (1.543 … 7.496 lbs)

Output variable

Output

-

Signal

digital output signal, Foundation Fieldbus protocol

-

Physical layer

according to IEC 61158-2

Cycle time

min. 1 s (dependent on the parameter setting)

-

Damping (63 % of the input variable)

0 … 999 s, adjustable

-

Fulfilled NAMUR recommendations

NE

43

Channel Numbers

-

Channel 1

Primary value

-

Channel 2

Secondary value 1

-

Channel 3

Secondary value 2

Transmission rate

31.25 Kbit/s

Current value

10 mA, ±0.5 mA

Resolution, digital

> 1

mm (0.039 in)

VEGAPULS

67 • Foundation Fieldbus

53

10 Supplement

32941

-

EN

-100514

Advertising