Start your parameter adjustment with the following menu items
of the basic adjustment:

Proceed as follows:

1 Move from the measured value display to the main menu

by pushing [OK].

Basic adjustment

Display
Diagnostics
Service
Info

2 Select the menu item "Basic adjustment" with [->] and

confirm with [OK]. Now the menu item "Min. adjustment" is
displayed.

Min. adjustment

0.00 %

=

10.000 m(d)

8.000 m(d)

3 Prepare the % value for editing with [OK] and set the

cursor to the requested position with [->]. Set the
requested percentage value with [+] and save with [OK].
The cursor jumps now to the distance value.

4 Enter the suitable distance value in m for the empty vessel

(e.g. distance from the sensor to the vessel bottom)
corresponding to the percentage value.

5 Save the settings with [OK] and move to "Max. adjustment"

with [->].

Proceed as follows:

Max. adjustment

100.00 %

=

1.000 m(d)

2.000 m(d)

1 Prepare the % value for editing with [OK] and set the

cursor to the requested position with [->]. Set the
requested percentage value with [+] and save with [OK].
The cursor jumps now to the distance value.

2 Enter the appropriate distance value in m (corresponding

to the percentage value) for the full vessel. Keep in mind
that the max. level must lie below the dead band.

Carrying out min. ad-
justment

Carrying out max. ad-
justment

VEGAFLEX

66 • Foundation Fieldbus

29

6 Set up with the indicating and adjustment module PLICSCOM