VEGA VEGAFLEX 66 (-110…+400°C) Foundation Fieldbus User Manual

Page 55

Advertising
background image

Secondary_value_1

Calibration

Lowest Point

Calibration

Highest Point

Sensor_value

cal_level_lo

cal_level_hi

Calibration
Lowest Point

Calibration
Highest Point

Sensor reference plane

cal_level_lo [%]

cal_level_hi [%]

Fig. 27: Adjustment VEGAFLEX 66

Parameter list
The following list contains the most important parameters and their meaning:

l

primary_value

-

This is the process value after adjustment and Linearization with the status of the
transducer block

-

It is the input for the AIFB when CHANNEL = 1 is selected

-

The unit is defined in "primary_value_unit"

l

primary_value_unit

-

Selected unit code for "primary_value"

l

secondary_value_1

-

This is the process value after adjustment with the status of the transducer block

-

It is the input for the AIFB when CHANNEL = 2 is selected

-

The unit is defined in "secondary_value_2_unit"

l

secondary_value_1_unit

-

Selected unit code for "secondary_value_1"

l

secondary_value_2

-

This is the distance value (sensor_value) with the status of the transducer block

VEGAFLEX

66 • Foundation Fieldbus

55

10 Supplement

32765

-

EN

-080716