background image

Ambient conditions

Ambient, storage and transport temperature

-40 … +80 °C (-40 … +176 °F)

Process conditions

Process pressure

-1 … +40 bar/-100 … +4000 kPa (-
-14.5 … +580 psig), depending on the process
fitting

Process temperature (thread or flange temperature)

-

FKM (Viton)

-40 … +150 °C (-40 … +302 °F)

-

EPDM

-40 … +150 °C (-40 … +302 °F)

-

FFKM (Kalrez 6375)

-20 … +150 °C (-4 … +302 °F)

The measurement error from the process condi-
tions is in the specified pressure and temperature
range of below 1 %.

0 °C

(32 °F)

40 °C

(104 °F)

20 °C

(58 °F)

60 °C

(140 °F)

80 °C

(176 °F)

50 °C

(122 °F)

-40 °C

(-40 °F)

100 °C

(212 °F)

150 °C

(302 °F)

1

2

Fig. 32: Ambient temperature - Process temperature

1

Ambient temperature

2

Process temperature (depending on the seal material)

Electromechanical data - version IP 66/IP 67 and IP 66/IP 68; 0.2 bar

Cable entry/plug

4)

-

Single chamber housing

l

1 x cable gland M20 x 1.5 (cable: ø 5 … 9 mm),
1 x blind stopper M20 x 1.5

or:

l

1 x closing cap M20 x 1.5; 1 x blind stopper
M

20 x 1.5

or:

l

1 x closing cap ½ NPT, 1 x blind plug ½ NPT

or:

l

1 x plug (depending on the version), 1 x blind
stopper M20 x 1.5

4)

Depending on the version M12 x 1, according to DIN 43650, Harting, 7/