VEGA VEGAPULS SR 68 4 … 20 mA_HART two-wire User Manual

Page 70

Advertising
background image

70

11 Supplement

VEGAPULS SR 68 • 4 … 20 mA/HART two-wire

38294-EN-130624

3

4

2

1

Fig. 55: Data of the input variable
1 Reference plane

2 Measured variable, max. measuring range

3 Antenna length

4 Useful measuring range

Max. measuring range

30 m (98.43 ft)

Recommended meas. range depending on the antenna diameter

Ʋ ø 40 mm (1.575 in)

up to 15 m (49.21 ft)

Ʋ ø 48 mm (1.89 in)

up to 20 m (65.62 ft)

Ʋ ø 75 mm (2.953 in), 95 mm (3.74 in)

up to 30 m (98.43 ft)

Ʋ Parabolic antenna

up to 30 m (98.43 ft)

Output variable
Output signal

4 … 20 mA/HART

Range of the output signal

3.8 … 20.5 mA/HART (default setting)

Fulfilled HART specification

7.0

Signal resolution

0.3 µA

Failure signal current output (adjustable) mA-value unchanged 20.5 mA, 22 mA, < 3.6 mA
Max. output current

22 mA

Starting current

≤ 3.6 mA; ≤ 10 mA for 5 ms after switching on

Load

see load diagram under Power supply

Damping (63 % of the input variable),

adjustable

0 … 999 s