VEGA VEGAPULS SR 68 4 … 20 mA_HART two-wire User Manual

Page 75

Advertising
background image

75

11 Supplement

VEGAPULS SR 68 • 4 … 20 mA/HART two-wire

38294-EN-130624

Integrated clock
Date format

Day.Month.Year

Time format

12 h/24 h

Time zone Ex factory

CET

Measurement electronics temerature
Resolution

1 °C (1.8 °F)

Accuracy

±1 °C (1.8 °F)

Voltage supply
Operating voltage U

B

Ʋ Non-Ex instrument

9.6 … 36 V DC

Ʋ Ex-ia instrument

9.6 … 30 V DC

Ʋ Ex-d-ia instrument

14 … 36 V DC

Ʋ Ex-d-ia instrument with ship approval 15 … 36 V DC

Operating voltage U

B

- illuminated display and adjustment module

Ʋ Non-Ex instrument

16 … 36 V DC

Ʋ Ex-ia instrument

16 … 30 V DC

Ʋ Ex-d-ia instrument

20 … 36 V DC

Interpolation protection

Integrated

Permissible residual ripple - Non-Ex, Ex-ia instrument

Ʋ for 9.6 V< U

B

< 14 V

≤ 0.7 V

eff

(16 … 400 Hz)

Ʋ for 18 V< U

B

< 36 V

≤ 1.0 V

eff

(16 … 400 Hz)

Permissible residual ripple - Ex-d-ia instrument

Ʋ for 18 V< U

B

< 36 V

≤ 1 V

eff

(16 … 400 Hz)

Load resistor

Ʋ Calculation

(U

B

- U

min

)/0.022 A

Ʋ Example - Non-Ex instrument with

U

B

= 24 V DC

(24 V - 9.6 V)/0.022 A = 655 Ω

Electrical protective measures
Protection, depending on housing version

Ʋ Plastic housing

IP 66/IP 67

Ʋ Aluminium housing, stainless steel

housing - investment casting, stain-

less steel housing - electro-polished

IP 66/IP 68 (0.2 bar)

5)

Ʋ Aluminium and stainless housing, in-

vestment casting (optionally available)

IP 66/IP 68 (1 bar)

Overvoltage category

III

Protection class

III

Approvals
Instruments with approvals can have different technical data depending on the version.

5)

The prerequisites for maintaining the protection rating are a suitable cable as well as correct mounting.

Advertising