VEGA VEGAPULS series 60 Recurring function test User Manual

Page 12

Advertising
background image

Ratio "V"

Correction value (dB)

1.1

+0

.8

1.2

+1

.5

1.3

+2

.3

1.4

+3

1.5

+3

.5

1.6

+4

1.7

+4

.6

1.8

+5

1.9

+5

.6

2.0

+6

Example
During setup, the level echo had 32 dB. The distance [m] to the
medium was 12.9 m.

The actual level echo has 25 dB. The distance [m] to the medium is
15.8 m.

Division of the current distance [m] by the distance [m] during setup:
15.8 m : 12.9 m = 1.224

Round mathematically to one position after the decimal point: 1.224 -->
1.2

Correction value for the ratio (1.2): + 1.5

Calculation of the corrected value of the amplitude: 25 dB + 1.5 = 26.5 dB

The result of the example (26.5 dB) is thus within the permissible
tolerance range of - 6 dB (32 dB - 6 dB = 26 dB)

In this example, the test point would be successfully fulfilled.

The following criteria must correspond when comparing the echo data:

l

If there are false echoes in front of the level echo (highest useful
echo probability), they must have a useful echo probability of 0 %.

l

The amplitude [dB] (with correction factor) of the actual level echo
(highest useful echo probability) corresponds to the respective
value of the level echo from the setup (tolerance max. -6 dB). This
means that the actual level echo can be higher, but only max. 6 dB
lower than the level echo during setup.

12

Recurring function test • for VEGAPULS series 60

3 Sequence of the recurring function test

36553

-EN

-100225

Advertising