10 supplement, 1 technical data – VEGA PLICSMOBILE T61 User Manual

Page 32

Advertising
background image

32

10 Supplement

PLICSMOBILE T61 • External GSM/GPRS radio unit

37700-EN-130228

10 Supplement

10.1 Technical data

General data
316L corresponds to 1.4404 or 1.4435, 316Ti corresponds to 1.4571
Materials

Ʋ Housing

plastic PBT, Alu die-casting, 316L

Ʋ Ground terminal

316Ti/316L

Weight

Ʋ Plastic housing

595 g (1.311 lbs); 633 g (1.396 lbs) with external an-

tenna

Ʋ Aluminium housing

1231 g (6.415 lbs)

Voltage supply
Operating voltage

1)

8 … 32 V DC

Power consumption

2)

Ʋ Power saving mode (9 V/12 V)

0.18 mW/0.3 mW

Ʋ Power saving mode (24 V/32 V)

1.8 mW/3.7 mW

Ʋ Permanent operation

1.1 W

Ʋ Peak power (measured value trans-

mission)

5.1 W

Power requirement

3)

Ʋ Measurement cycle incl. transmission 20 mWh

Battery pack (optional)
Battery type

Lithium (not chargeable)

VEGA order code

PM-BATT.

Operating voltage

18 V DC

Capacitance

approx. 3.5 Ah

Accumulator pack with charging electronics (optional)
Accumulator type

6x NiMH series AA (Mignon)

Manufacturer/series

Panasonic/Evolta

VEGA order code

PM-AKKUAA

Capacitance

2050 mAh

Nominal voltage accumulator pack

7.2 V DC

Charging voltage accumulator pack

20… 32 V DC

Ambient temperature

Ʋ Charging

0 … +55 °C (32 … +131 °F)

1)

When the instrument is powered by an external voltage supply, make sure the voltage supply unit has a suf-

ficient current carrying capacity. With a voltage supply <9.6 V, current peaks of up to 2 A must be expected.

2)

The listed power specifications include the voltage supply of a HART sensor with 20 mA

3)

The listed energy requirement includes the voltage supply of a HART sensor (VEGAPULS 61 with 4 mA (multi-

drop mode) and 12 V operating voltage

Advertising