VEGA PLICSMOBILE T61 User Manual

Page 34

Advertising
background image

34

10 Supplement

PLICSMOBILE T61 • External GSM/GPRS radio unit

37700-EN-130228

Ʋ Electronics housing

– 1 x cable gland M20 x 1.5 (cable ø 5 … 9 mm), 1 x

SMA antenna connection (optional), 1 x plug for sen-

sor connection

or:

– 1 x closing cap ½ NPT, 1 x SMA antenna connection

(optional), 1 x plug for sensor connection

Spring-loaded terminals for wire cross-section

Ʋ Massive wire, cord

0.2 … 2.5 mm² (AWG 24 … 14)

Ʋ Stranded wire with end sleeve

0.2 … 1.5 mm² (AWG 24 … 16)

Sensor connection cable

Ʋ Length

25 m

Ambient conditions
Ambient temperature

Ʋ Instrument in general

-25 … +60 °C (-13 … +140 °F)

Ʋ USB interface

0 … +60 °C (+32 … +140 °F)

Storage and transport temperature

-25 … +80 °C (-13 … +176 °F)

Electrical protective measures
Protection rating

IP 66/IP 67

5)

Electrical separating measures
Reliable separation according to VDE 0106 part 1 between power supply and input

Ʋ Reference voltage

50 V

Ʋ Isolation resistance

1.5 kV

Radio approvals
Radio approvals of the integrated GSM modem

Ʋ FCC ID

RI7GE865

Ʋ IC (Industry Canada)

5131 A-GE865

Approvals
Instruments with approvals can have different technical data depending on the version.
For that reason the associated approval documents of these instruments have to be carefully

noted. They are part of the delivery or can be downloaded under www.vega.com via "VEGA Tools"

and "serial number search" as well as via "Downloads" and "Approvals".

5)

A suitable cable is the prerequisite for maintaining the protection rating.

Advertising