VEGA VEGABAR 66 Foundation Fieldbus User Manual

Page 55

Advertising
background image

55

10 Supplement

VEGABAR 66 • Foundation Fieldbus

36740-EN-130321

0,15 %

-0,15 %

-40°C

-20°C

20°C

40°C

60°C

80°C

Fig. 31: Thermal change, current output

Long-term stability (according to DIN 16086 and IEC 60770-1)
Applies to digital HART interface as well as to analogue current output 4 … 20 mA under refer-

ence conditions. Specifications refer to the set span. Turn down (TD) is the relation nominal meas-

uring range/set span.
Long-term drift of the zero signal:

Ʋ For one year

< 0.05 % x TD

Ʋ For five years

< 0.1 % x TD

Ʋ For ten years

< 0.2 % x TD

Ambient conditions
Ambient, storage and transport temperature

Ʋ Version with connection tube

-40 … +80 °C (-40 … +176 °F)

Ʋ Version with suspension cable FEP,

PUR

-20 … +80 °C (-4 … +176 °F)

Ʋ Version with suspension cable PE

-20 … +60 °C (-4 … +140 °F)

Process conditions
The specifications of the pressure stage and product temperature are used as an overview. The

specifications on the type label are applicable.
Process pressure, transmitter

Ʋ with measuring ranges 0.1 bar

(1.45 psig) or 0.2 bar (2.9 psig)

max. 15 bar (217.6 psig) or max. 20 bar (290 psig)

12)

Ʋ with meas. ranges from 0.4 bar

(5.8 psig)

max. 25 bar (363 psig)

13)

Pressure stage, process fitting

Ʋ Threaded fitting

316L PN 3, PVDF PN 5

14)

Ʋ Thread

316L PN 25, PVDF unpressurized

Ʋ Lock fitting

Unpressurized

Ʋ Flange 316L

PN 16 or PN 40

Ʋ Flange GFK

10 bar

12)

Limited by the overpressure resistance of the measuring cell.

13)

Limitation by the pressure-tightness of the cable connection.

14)

Limited by the overpressure resistance of the measuring cell.

Advertising