Diagnostics, Service – VEGA VEGADIF 65 Profibus PA User Manual
Page 54
54
6 Adjustment with the display and adjustment module PLICSCOM
VEGADIF 65 • Profibus PA
36129-EN-130417
Display
Basic adjustment
2
▶
Display
Diagnostics
Service
Info
Displayed value
2.1
Differential pressure
▼
Displayed value
2.1
PA-Out
Display unit
2.2
Volume
▼
l
▼
Scaling
2.3
0 % = 0.0
l
100 % = 100.0
l
Backlight
2.4
Switched off
▼
Diagnostics
Basic adjustment
3
Display
▶
Diagnostics
Service
Info
Peak value
3.1
p-min.: -5.8 mbar
p-max.: 167.5 mbar
T-min.: -12.5 °C
T-max.: +85.5 °C
Sensor status
3.2
OK
Trend curve
3.3
Start trend curve?
Totalizer
3.4
0.0000 10
00
gal
Modify settings?
Part sum counter
3.5
0.0000 10
00
gal
Modify settings?
Service
Basic adjustment
4
Display
Diagnostics
▶
Service
Info
Additional PA value
4.1
Secondary Value 1
Out-Scale-Unit
4.2
Volume
l
PA-Out-Scale
4.3
100.00 lin %
= 0.0 l
0.00 lin %
= 100.0 l
Simulation
4.2
Start simulation
▼
Reset
4.3
Select reset
▼
Language
4.4
Deutsch
▼
Copy sensor data
4.7
Copy sensor data?
PIN
4.8
Enable?