VEGA VEGABAR 54 4 … 20 mA User Manual

Page 57

Advertising
background image

57

10 Supplement

VEGABAR 54 • 4 … 20 mA

36725-EN-130321

Nominal range

Overload capacity, max.

pressure

Overload capacity, min. pres-

sure

0 … 60 bar/0 … 6000 kPa

200 bar/20 MPa

0 bar abs.

Nominal measuring ranges and overload capability in psig
The specifications are only an overview and refer to the measuring cell. Limitations due to the ma-

terial and version of the process fitting are possible. The specifications on the nameplate apply.

Nominal range

Overload capacity, max.

pressure

Overload capacity, min. pres-

sure

Gauge pressure
0 … +1.5 psig

+200 psig

-3 psig

0 … +3 psig

+290 psig

-6 psig

0 … +6 psig

+430 psig

-12 psig

0 … +15 psig

+500 psig

-15 psig

0 … +35 psig

+725 psig

-15 psig

0 … +70 psig

+950 psig

-15 psig

0 … +150 psig

+1300 psig

-15 psig

0 … +350 psig

+1900 psig

-15 psig

0 … +900 psig

+2900 psig

-15 psig

-15 … 0 psig

+500 psig

-15 psig

-15 … +25 psig

+700 psig

-15 psig

-15 … +70 psig

+950 psig

-15 psig

-15 … +150 psig

+1300 psig

-15 psig

-15 … +350 psig

+1900 psig

-15 psig

-15 … +900 psig

+2900 psig

-15 psig

-0.7 … +0.7 psig

+200 psig

-3 psig

-1.5 … +1.5 psig

+290 psig

-6 psig

-3 … +3 psig

+430 psig

-12 psig

-7 … +7 psig

+500 psig

-15 psig

Absolute pressure
0 … 15 psi

500 psi

0 psi

0 … 35 psi

700 psi

0 psi

0 … 70 psi

900 psi

0 psi

0 … 150 psi

1300 psi

0 psi

0 … 350 psi

1900 psi

0 psi

0 … 900 psi

2900 psi

0 psi

Reference conditions and actuating variables (according to DIN EN 60770-1)
Reference conditions according to DIN EN 61298-1

Ʋ Temperature

+15 … +25 °C (+59 … +77 °F)

Ʋ Relative humidity

45 … 75 %

Advertising