59

10 Supplement

VEGABAR 54 • 4 … 20 mA

36725-EN-130321

0,15 %

-0,15 %

-40°C

-20°C

20°C

40°C

60°C

80°C

Fig. 20: Thermal change, current output

Long-term stability (according to DIN 16086 and IEC 60770-1)
Applies to digital HART interface as well as to analogue current output 4 … 20 mA under refer-

ence conditions. Specifications refer to the set span. Turn down (TD) is the relation nominal meas-

uring range/set span.
Long-term drift of the zero signal:

Ʋ For one year

< 0.05 % x TD

Ʋ For five years

< 0.1 % x TD

Ʋ For ten years

< 0.2 % x TD

Ambient conditions
Ambient, storage and transport temperature

Ʋ Standard version

-40 … +80 °C (-40 … +176 °F)

Ʋ Versions IP 66/IP 68 (1 bar) and IP 68

(25 bar), connection cable PUR

-20 … +80 °C (-4 … +176 °F)

Ʋ Version IP 66/IP 68 (1 bar), connec-

tion cable PE

-20 … +60 °C (-4 … +140 °F)

Process conditions
The specifications of the pressure stage and product temperature are used as an overview. The

specifications on the type label are applicable.
Pressure stage, process fitting

Ʋ Thread 316L

PN 60

Ʋ Thread 316L 1" for ball valve fitting

PN 40

Ʋ PMC 316L

PN 10

Ʋ Flange 316L

PN 40

Product temperature depending on the measuring cell seal

14)

Measuring cell seal

Product temperature

FKM (VP2/A)

-20 … +120 °C (-4 … +248 °F)

EPDM (A+P 75.5/KW75F)

-40 … +120 °C (-40 … +248 °F)

FFKM (Kalrez 6375)

-20 … +120 °C (-4 … +248 °F)

FFKM (Perlast G75S)

-15 … +120 °C (-4 … +248 °F)

14)

With process fitting PVDF, max. 100 °C (212 °F).