VEGA VEGABAR 51 4 … 20 mA_HART User Manual

Page 52

Advertising
background image

52

10 Supplement

VEGABAR 51 • 4 … 20 mA/HART

36713-EN-130321

Nominal range

Overload capacity, max.

pressure

Overload capacity, min. pres-

sure

0 … 5 bar/0 … 500 kPa

35 bar/3500 kPa

0 bar abs.

0 … 10 bar/0 … 1000 kPa

80 bar/8000 kPa

0 bar abs.

0 … 25 bar/0 … 2500 kPa

80 bar/8000 kPa

0 bar abs.

Nominal measuring ranges and overload capacity in psi
The specifications are only an overview and refer to the measuring cell. Limitations due to the ma-

terial and version of the process fitting are possible. The specifications on the nameplate apply.

Nominal range

Overload capacity, max.

pressure

Overload capacity, min. pres-

sure

Gauge pressure
0 … +5.801 psig

+29.00 psig

-14.50 psig

0 … +14.50 psig

+145.0 psig

-14.50 psig

0 … +36.26 psig

+507.6 psig

-14.50 psig

0 … +1450 psig

+2901 psig

-14.50 psig

0 … +3626 psig

+7252 psig

-14.50 psig

0 … +5802 psig

+17404 psig

-14.50 psig

0 … +72.52 psig

+507.6 psig

-14.5 psig

0 … +145.0 psig

+1160 psig

-14.50 psig

0 … +362.6 psig

+1160 psig

-14.50 psig

0 … +580.2 psig

+1160 psig

-14.50 psig

0 … +870.2 psig

+2901 psig

-14.50 psig

-14.50 … 0 psig

+145.0 psig

-14.50 psig

-14.50 … +1.5 psig

+311.8 psig

-14.50 psig

-14.50 … +362.6 psig

+507.6 psig

-14.50 psig

-14.50 … +145.0 psig

+1160 psig

-14.50 psig

-14.50 … +362.6 psig

+1160 psig

-14.50 psig

-14.50 … +870.2 psig

+2901 psig

-14.50 psig

-2.901 … +2.901 psig

+2.901 psig

-14.50 psig

-7.252 … +7.252 psig

+145.0 psig

-14.50 psig

Absolute pressure
0 … 14.50 psi

145.0 bar

0 psi

0 … 36.26 bar

507.6 psi

0 psi

0 … 72.52 psi

507.6 psi

0 psi

0 … 145.0 bar

1160 psi

0 psi

0 … 362.6 psi

1160 bar

0 psi

Reference conditions and actuating variables (according to DIN EN 60770-1)
Reference conditions according to DIN EN 61298-1

Ʋ Temperature

+18 … +30 °C (+64 … +86 °F)