VEGA VEGABAR 82 Modbus and Levelmaster protocol - Operating Instructions User Manual

Page 64

Advertising
background image

64

10 Supplement

VEGABAR 82 • Modbus and Levelmaster protocol

46294-EN-131107

Measuring cell seal

Product temperature - standard

version

Product temperature - version

with extended temperature range

EPDM (A+P 75.5/KW75F)

-40 … +130 °C (-40 … +266 °F)
1 h: 140 °C/284 °F cleaning tem-

perature

-40 … +150 °C (-40 … +302 °F)

EPDM (ET 7056)

-40 … +130 °C (-40 … +266 °F)
1 h: 140 °C/284 °F cleaning tem-

perature

-

FFKM (Kalrez 6375)

-20 … +130 °C (-4 … +266 °F)

-20 … +150 °C (-4 … +302 °F)

FFKM (Perlast G75S)

-15 … +130 °C (-4 … +266 °F)

-15 … +150 °C (5 … +302 °F)

FFKM (Perlast G75B)

-15 … +130 °C (-4 … +266 °F)

-15 … +150 °C (5 … +302 °F)

FFKM (Chemraz 535)

-30 … +130 °C (-22 … +266 °F)

-

FEPM (Fluoraz SD890)

-5 … +130 °C (-22 … +266 °F)

-

Product temperature depending on the ambient temperature

Ambient temperature

Product temperature

+50 °C (+122 °F)

+150 °C (+302 °F)

+80 °C (+176 °F)

+100 °C (+212 °F)

Mechanical stress, depending on the instrument version
Vibration resistance

4 g at 5 … 200 Hz according to EN 60068-2-6 (vibration

with resonance)

Shock resistance

100 g, 6 ms according to EN 60068-2-27 (mechanical

shock)

Electromechanical data - version IP 66/IP 67 and IP 66/IP 68; 0.2 bar
Options of the cable entry

Ʋ Cable gland

M20 x 1.5

Ʋ Cable diameter (options)

5 … 9 mm (0.20 … 0.35 in)
6 … 12 mm (0.24 … 0.47 in)
10 … 14 mm (0.39 … 0.55 in)

Ʋ Cable entry

½ NPT

Ʋ Blind plug

M20 x 1.5; ½ NPT

Ʋ Closing cap

M20 x 1.5; ½ NPT

Plug options

Ʋ Signal circuit

Plug M12 x 1, according to ISO 4400, Harting HAN,

7/8" FF

Ʋ Indication circuit

M12 x 1 plug

Wire cross-section (spring-loaded terminals)

Ʋ Massive wire, cord

0.2 … 2.5 mm² (AWG 24 … 14)

Ʋ Stranded wire with end sleeve

0.2 … 1.5 mm² (AWG 24 … 16)

Advertising