VEGA VEGABAR 82 Modbus and Levelmaster protocol - Operating Instructions User Manual

Page 66

Advertising
background image

66

10 Supplement

VEGABAR 82 • Modbus and Levelmaster protocol

46294-EN-131107

Ʋ mounted into the housing without

cover

IP 40

Materials

Ʋ Housing

ABS

Ʋ Inspection window

Polyester foil

Interface to the external display and adjustment unit
Data transmission

digital (I²C-Bus)

Configuration, connection cable

4-wire, screened

Cable length max.

Ʋ Sensors with signal output

4 … 20 mA, 4 … 20 mA/HART

50 m

Ʋ Sensors with signal output Profibus

PA, Foundation Fieldbus

25 m

Interface to the slave sensor
Data transmission

digital (I²C-Bus)

Configuration, connection cable

4-wire, screened

Cable length max.

25 m

Integrated clock
Date format

Day.Month.Year

Time format

12 h/24 h

Time zone Ex factory

CET

Rate deviation max.

10.5 min/year

Measurement electronics temerature
Resolution

1 °C (1.8 °F)

Accuracy

±1 °C (1.8 °F)

Voltage supply
Operating voltage

8 … 30 V DC

Power consumption

< 500 mW

Interpolation protection

Integrated

Potential connections in the instrument
Electronics

Not non-floating

Ground terminal

Galvanically connected with the process fitting

Electrical protective measures

Housing material

Version

IP-protection class

NEMA protection

Plastic

Single chamber

IP 66/IP 67

NEMA 4X/6P

Double chamber

IP 66/IP 67

NEMA 4X

Advertising