9 supplement, 1 technical data – VEGA VEGABAR series 80 External housing User Manual

Page 17

Advertising
background image

17

9 Supplement

External housing • For pressure transmitter VEGABAR series 80

45081-EN-131119

9 Supplement

9.1 Technical data

General data
Material 316L corresponds to 1.4404 or 1.4435
Materials, non-wetted parts

Ʋ Electronics housing

plastic PBT (Polyester), 316L

Ʋ Base

plastic PBT (Polyester), 316L

Ʋ Wall mounting plate

plastic PBT (Polyester), 316L

Ʋ Seal between base and wall mounting

plate

TPE (fixed connected)

Ʋ Seal between housing and housing

cover

Silicone (plastic housing), NBR (stainless steel housing)

Ʋ Ground terminal

316L

Torque of base screws for plastic housing

max.

5 Nm (3.688 lbf ft)

Weight approx.

0.7 … 2.0 kg (1.543 … 4.409 lbs), depending on housing

material

Process conditions
Ambient, storage and transport temperature

Ʋ without display and adjustment

module

-40 … +80 °C (-40 … +176 °F)

Ʋ With display and adjustment module -20 … +70 °C (-4 … +158 °F)

Electromechanical data
Options of the cable entry

Ʋ Cable gland

M20 x 1.5 (cable: ø 5 … 9 mm)

Ʋ Cable entry

½ NPT

Ʋ Blind plug

M20 x 1.5; ½ NPT

Ʋ Closing cap

M20 x 1.5; ½ NPT

Wire cross-section (spring-loaded

terminals)

up to 2.5 mm² (AWG 14)

Electrical protective measures
Protection, depending on housing version

Ʋ Plastic housing

IP 66/IP 67

Ʋ Stainless steel housing

IP 66/IP 68 (0.2 bar)

2)

2)

The prerequisites for maintaining the protection rating are a suitable cable as well as correct mounting.