4 Mounting

External housing • For pressure transmitter VEGABAR series 80

45081-EN-131119

4 Mounting

4.1 Mounting preparations

The following tools are required for mounting the external housing.

Plastic housing:

Hexagon spanner size 4

Fork wrench, wrench size 19

Stainless steel housing:

Fork wrench, wrench size 8

Fork wrench, wrench size 19

4.2 Exchange of the electronics module

The electronics module is located in the electronics compartment.

The below illustration shows the position of the electronics compart-

ment in an external housing.

1

Fig. 2: Single chamber housing
1 Position of the electronics compartment

Proceed as follows to remove the electronics module from the existing

housing:
1. Switch off power supply
2. Unscrew housing cover of the electronics compartment
3. Disconnect the connection cables according to the operating

instructions manual of the respective sensor

4. Loosen the two holding screws with a screwdriver (Torx size T 10

or slotted screwdriver size 4)