Fc17 report slave id, Fc43 sub 14, read device identification – VEGA VEGAFLEX 86 Modbus and Levelmaster protocol Coax probe User Manual
Page 77
77
11 Supplement
VEGAFLEX 86 • Modbus and Levelmaster protocol
42288-EN-130314
Parameter
Length
Code/Data
Byte Number
1 Byte
2*N
Register Value
N*2 Bytes
Data
Response:
Parameter
Length
Code/Data
Function Code
1 Byte
0x10
Sub Function Code
2 Bytes
0x0000 to 0xFFFF
Data
2 Bytes
0x01 to 0x7B
FC17 Report Slave ID
With this function code, the Slave ID can be queried.
Request:
Parameter
Length
Code/Data
Function Code
1 Byte
0x11
Response:
Parameter
Length
Code/Data
Function Code
1 Byte
0x11
Byte Number
1 Byte
Slave ID
1 Byte
Run Indicator Status
1 Byte
FC43 Sub 14, Read Device Identification
With this function code, the Device Identification can be queried.
Request:
Parameter
Length
Code/Data
Function Code
1 Byte
0x2B
MEI Type
1 Byte
0x0E
Read Device ID Code
1 Byte
0x01 to 0x04
Object ID
1 Byte
0x00 to 0xFF
Response:
Parameter
Length
Code/Data
Function Code
1 Byte
0x2B
MEI Type
1 Byte
0x0E
Read Device ID Code
1 Byte
0x01 to 0x04
Confirmity Level
1 Byte
0x01, 0x02, 0x03, 0x81, 0x82, 0x83
More follows
1 Byte
00/FF
Next Object ID
1 Byte
Object ID number
Number of Objects
1 Byte