9 Supplement

VEGASWING 66 • - two-wire

43758-EN-130322

Ʋ Colour - standard PE

Black

Ʋ Colour - standard PUR

Blue

Ʋ Colour - Ex-version

Blue

Adjustment elements
Mode switch

Ʋ Max.

Max. detection or overflow/overfill protection

Ʋ Min.

Min. detection or dry run protection

Sensitivity switch

Ʋ ≥ 0.5

0.47 … 2.5 g/cm³ (0.0163 … 0.9 oz/in³)

Ʋ ≥ 0.7

0.7 … 2.5 g/cm³ (0.025 … 0.9 oz/in³)

Test key

To activate the test process

Voltage supply
Operating voltage

9.6 … 35 V DC (via the processing system)

Electrical protective measures
Protection rating

Ʋ Plastic housing

IP 66/IP 67

Ʋ Aluminium and stainless steel stand-

ard

IP 66/IP 68 (0.2 bar)

5)

Ʋ Aluminium and stainless housing

(optionally available)

IP 66/IP 68 (1 bar)

Overvoltage category

III

Protection class

II

Approvals
Instruments with approvals can have different technical data depending on the version.
For that reason the associated approval documents of these instruments have to be carefully

noted. They are part of the delivery or can be downloaded under www.vega.com via "VEGA Tools"

and "serial number search" as well as via "Downloads" and "Approvals".

5)

A suitable cable is the prerequisite for maintaining the protection rating.