3 Product description

VEGASWING 66 • - two-wire

43758-EN-130322

3.2 Principle of operation

VEGASWING 66 is a point level sensor with tuning fork for level

detection.
It is designed for industrial use in all areas of process technology and

can be used in liquids. It is particularly suitable for applications with

high temperatures up to 450 °C (842 °F) and high process pressure

up to 160 bar (2320 psig).
Typical applications are overfill and dry run protection. The small

tuning fork allows use in pipelines. Thanks to its simple and rugged

measuring system, VEGASWING 66 is virtually unaffected by the

chemical and physical properties of the liquid.
It functions even under difficult conditions such as turbulence, foam

generation, buildup, strong external vibration or changing products.
Function monitoring

The electronics module of VEGASWING 66 continuously monitors via

frequency evaluation the following criteria:

Strong corrosion or damage on the tuning fork

Loss of vibration

Line break to the vibrating drive

If one of these faults is detected, the electronics signals it via a

defined current to the signal conditioning instrument. The connection

cable to the sensor is also monitored for line break and short-circuit.

The tuning fork is piezoelectrically energised and vibrates at its

mechanical resonance frequency of approx. 1200 Hz. The piezos are

fixed mechanically and are hence not subject to temperature shock

limitations. The frequency changes when the tuning fork is covered

by the medium. This change is detected by the integrated electronics

module, transferred as a current value to the processing system and

converted there into a switching command.

Depending on your requirements, VEGASWING 66 with two-wire

electronics can be connected to different signal conditioning instru-

ments. Compatible signal conditioning instruments are listed in

chapter "Technical data".
The data for power supply are specified in chapter "Technical data".

3.3 Operation

With the factory setting, products with a density > 0.07 g/cm³

(0.025 lbs/in³) can be detected. The instrument can be adapted to

products with lower density.
On the electronics module you will find the following display and

adjustment elements:

Signal lamp for indication of the operating condition (green)

Signal lamp for indication of the switching condition (yellow)

Control lamp for fault indication (red)

DIL switch for sensitivity adjustment

Mode switch for selecting the switching behaviour (min./max.)

Application area

Functional principle

Voltage supply