VEGA VEGABAR 81 HART and accumulator pack - Operating Instructions User Manual

Page 51

Advertising
background image

51

11 Supplement

VEGABAR 81 • HART and accumulator pack

45026-EN-131107

Adjustment range of the zero/span adjustment relating to the nominal measuring range:

Ʋ zero

-20 … +95 %

Ʋ span

-120 … +120 %

1)

Ʋ Difference between zero and span

max. 120 % of the nominal range

Recommended max. turn down

20 : 1 (no limitation)

Nominal measuring ranges and overload capability in bar/kPa
The specifications are only an overview and refer to the measuring cell. Limitations due to the

material and version of the process fitting as well as the selected pressure type are possible. The

specifications on the nameplate apply.

Nominal range

Overload capacity, max.

pressure

Overload capacity, min. pres-

sure

Gauge pressure
0 … +0.4 bar/0 … +40 kPa

+2 bar/+200 kPa

-1 bar/-100 kPa

0 … +1 bar/0 … +100 kPa

+5 bar/+500 kPa

-1 bar/-100 kPa

0 … +2.5 bar/0 … +250 kPa

+10 bar/+1000 kPa

-1 bar/-100 kPa

0 … +10 bar/0 … +1000 kPa

+35 bar/+3500 kPa

-1 bar/-100 kPa

0 … +25 bar/0 … +2500 kPa

+50 bar/+5000 kPa

-1 bar/-100 kPa

0 … +40 bar/0 … +4000 kPa

+80 bar/+8000 kPa

-1 bar/-100 kPa

0 … +100 bar/0 … +10 MPa

+200 bar/+20 MPa

-1 bar/-100 kPa

0 … +250 bar/0 … +25 MPa

+500 bar/+50 MPa

-1 bar/-100 kPa

0 … +600 bar/0 … +60 kPa

+1200 bar/+120 MPa

-1 bar/-100 kPa

0 … +1000 bar/0 … +100 MPa

+1500 bar/+150 MPa

-1 bar/-100 kPa

-1 … 0 bar/-100 … 0 kPa

+5 bar/+500 kPa

-1 bar/-100 kPa

-1 … +1.5 bar/-100 … +150 kPa

+10 bar/+1000 kPa

-1 bar/-100 kPa

-1 … +10 bar/-100 … +1000 kPa

+80 bar/+8000 kPa

-1 bar/-100 kPa

-1 … +25 bar/-100 … +2500 kPa

+80 bar/+8000 kPa

-1 bar/-100 kPa

-1 … +40 bar/-100 … +4000 kPa

+80 bar/+8000 kPa

-1 bar/-100 kPa

-0.2 … +0.2 bar/-20 … +20 kPa

+2 bar/+200 kPa

-1 bar/-100 kPa

-0.5 … +0.5 bar/-50 … +50 kPa

+5 bar/+500 kPa

-1 bar/-100 kPa

Absolute pressure
0 … 1 bar/0 … 100 kPa

5 bar/+500 kPa

0 bar abs.

0 … 2.5 bar/0 … 250 kPa

10 bar/+1000 kPa

0 bar abs.

0 … 10 bar/0 … 1000 kPa

35 bar/+3500 kPa

0 bar abs.

0 … 25 bar/0 … 2500 kPa

50 bar/+5000 kPa

0 bar abs.

0 … 40 bar/0 … 4000 kPa

80 bar/8000 kPa

0 bar abs.

Nominal measuring ranges and overload capacity in psi

1)

Values less than -1 bar cannot be set.

Advertising