VEGA VEGAFLEX 86 Profibus PA User Manual

Page 56

Advertising
background image

56

6 Set up with the display and adjustment module

VEGAFLEX 86 • Profibus PA

44232-EN-130910

Menu item

Default value

Modified value

AI FB3 Target Mode

Auto

The instrument settings are copied with this function. The following

functions are available:

Read from sensor: Read data from sensor and store into the

display and adjustment module

Write into sensor: Store data from the display and adjustment

module back to the sensor

The following data or settings for adjustment of the display and ad-

justment module are saved:

All data of the menu "Setup" and "Display"

In the menu "Additional adjustments" the items "Reset, Date/Time"

Special parameters

The copied data are permanently saved in an EEPROM memory in

the display and adjustment module and remain there even in case of

power failure. From there, they can be written into one or more sen-

sors or kept as backup for a possible electronics exchange.
Note:

Before the data are stored in the sensor, a check is carried out to

determine if the data fit the sensor. If the data do not fit, a fault signal

is triggered or the function is blocked. When data are being written

into the sensor, the display shows which instrument type the data

originate from and which TAG-no. this sensor had.

In this menu item you can select the type and size of your probe from

a list of all possible probes. This is necessary to adapt the electronics

optimally to the probe.

In this menu item you gain access to the protected area where

you can enter special parameters. In exceptional cases, individual

parameters can be modified in order to adapt the sensor to special

requirements.
Change the settings of the special parameters only after having con-

tacted our service staff.

Additional adjustments -

Copy instrument settings

Additional adjustments -

Probe type

Additional adjustments -

Special parameters

Advertising