11 supplement – VEGA VEGAFLEX 86 Profibus PA User Manual

Page 90

Advertising
background image

90

11 Supplement

VEGAFLEX 86 • Profibus PA

44232-EN-130910

Process temperature

-196 … +450 °C (-321 … +842 °F)
The measurement error from the process conditions is in

the specified pressure and temperature range of below

1 %.

1

2

0°C

(32°F)

-40°C

(-104°F)

80°C

(176°F)

450°C

(842°F)

220°C

(428°F)

3

4

-196°C

(-384.8°F)

-20°C

(-68°F)

-110°C

(-230°F)

35°C

(95°F)

Fig. 64: Ambient temperature - process temperature (version -196 … +450 °C/-321 … +842 °F)
1 Ambient temperature

2 Process temperature (depending on the seal material)

3 Maximum permissible temperature - standard

4 Limited temperature range - plastic housing and stainless steel housing, electropolished

2

1

-100°C

(-148°F)

-200°C

(-328°F)

100 bar

(1450 psig)

200 bar

(2900 psig)

300 bar

(4350 psig)

400 bar

(5800 psig)

380 bar

(5510 psig)

350 bar

(5070 psig)

0°C

(32°F)

200°C

(392°F)

100°C

(212°F)

400°C

(752°F)

300°C

(572°F)

320 bar

(4640 psig)

450°C

(842°F)

Fig. 65: Process pressure - process temperature (version -196 … +450 °C/-321 … +842 °F)
1 Process temperature (depending on the seal material)

2 Process pressure

Vibration resistance

Ʋ Instrument housing

4 g at 5 … 200 Hz according to EN 60068-2-6 (vibration

with resonance)

Ʋ Rod probe

1 g with 5 … 200 Hz according EN 60068-2-6 (vibration

at resonance) with rod length 50 cm (19.69 in)

Advertising