VEGA VEGAFLEX 86 4 … 20 mA_HART - four-wire Coax probe User Manual

Page 69

Advertising
background image

69

11 Supplement

VEGAFLEX 86 • 4 … 20 mA/HART - four-wire

42285-EN-130314

Ʋ Process fitting with PPS GF 40

-1 … 6 bar/-100 … 600 kPa (-14.5 … 87 psi), depending

on the process fitting

Ʋ Process fitting with Al

2

O

3

-1 … +40 bar/-100 … +4000 kPa (-14.5 … +580 psig),

depending on the process fitting

Vessel pressure relating to the flange

nominal stage

see supplementary instructions manual "Flanges ac-

cording to DIN-EN-ASME-JIS"

Process temperature (thread or flange temperature)

Ʋ PPS GF 40

-40 … +80 °C (-40 … +176 °F)

Ʋ FKM (SHS FPM 70C3 GLT)

-40 … +150 °C (-40 … +302 °F)

Ʋ EPDM (A+P 75.5/KW75F)

-40 … +150 °C (-40 … +302 °F)

Ʋ Silicone FEP coated (A+P FEP-O-

SEAL)

-40 … +150 °C (-40 … +302 °F)

Ʋ FFKM (Kalrez 6375)

-20 … +150 °C (-4 … +302 °F)

Ʋ FFKM (Kalrez 6375) - with tempera-

ture adapter

-20 … +200 °C (-4 … +392 °F)

1

2

0°C

(32°F)

-40°C

(-104°F)

65°C

(149°F)

80°C

(176°F)

150°C

(302°F)

130°C

(266°F)

80°C

(176°F)

3

4

-40°C

(-104°F)

Fig. 34: Ambient temperature - process temperature, standard version
1 Ambient temperature

2 Process temperature (depending on the seal material)

3 Maximum permissible temperature - standard

4 Limited temperature range - plastic housing and stainless steel housing, electropolished

Advertising