The Duress Output switches to (-) ground when duress code is entered. You may use it to turn

ON an LED lamp and/ or a small buzzer to notify a guard; or connect it to a 24 hour Normally

Open protection zone of an alarm system.

Only one connection option is recommended. Make sure that the sink current does not

exceed the maximum rating of 100mA.

(E) DURESS OUTPUT

The Key Active Output switches to (-) ground

for 10 seconds whenever a key is touched.

You may use it to turn ON an LED lamp and

/or a small buzzer to notify a guard; or to

energize a relay to switch ON lights or trigger

an CCTV Camera to start recording.

Make sure that the relay for switching ON

lights has high enough isolation between

high voltage and low voltage to prevent

damage of the keypad.

Only one connection option is recommended.

Make sure the sink current does not exceed

the maximum rating of 100mA.

External power supply and isolation relay

are strictly necessary in driving high power

device, such as lights.