Use the Normally Open (N.O.) output contact to shunt a Normally Closed (N.C.) protection

zone of an alarm system.

Set output contact to Start / Stop Mode (Programming Option 52, Output Mode=0).

Use the (N.O.) or (N.C.) output contact to make arm-disarm control of an alarm system.

Consult your alarm control panel manual for the appropriate output contact to be used in arm-

disarm control.

Usually set output 2 to Momentary mode (Programming Option 521, Location 52, Output

Mode=1) for multi station systems and Start / Stop mode (Programming Option 520, Location

52, Output Mode=0) for single station systems.

(F) OUTPUT 2 OR OUTPUT 3

( i ) Shunting an N.C. Zone

( ii ) Alarm System Arm-Disarm Control