User control interface, User control interface -18, 9066 functional description – Cobalt Digital COMPASS 9066 Upconverter User Manual

Page 22

Advertising
background image

1

9066 Functional Description

1-18

9066 PRODUCT MANUAL

9066-OM (V4.5)

User Control Interface

Figure 1-8 shows the user control interface options for the 9066. These
options are individually described below.

Note:

All user control interfaces described here are cross-compatible and can oper-
ate together as desired. Where applicable, any control setting change made
using a particular user interface is reflected on any other connected interface.

Figure 1-8 9066 User Control Interface

Computer
with NIC

OGCP-9000 Control Panel

or

OGCP-9000/CC Control Panel

20-Slot Frame with MFC-8320-N network
controller card

LAN

Card Edge Controls
9066 card can be
controlled using built-in
card edge controls

In conjunction with a frame equipped
with an MFC-8320-N network
controller card, 9066 card can be
remotely controlled over a LAN

Remote Control Panel
Using the Control Panel,
9066 card can be remotely
controlled over a LAN

DashBoard™ Remote Control
Using a computer with
DashBoard™ installed, 9066
card can be remotely controlled
over a LAN

Note: • To communicate with DashBoard™ or a Remote Control Panel, the frame must have the optional

MFC-8320-N network controller card installed.

• DashBoard™ and the Remote Control Panels provide network control of the 9066 as shown. The

value displayed at any time on the card, or via DashBoard™ or a Control Panel is the actual value
as set on the card, with the current value displayed being the actual value as effected by the card.
Parameter changes made by any of these means are universally accepted by the card (for
example, a change made using the card edge controls will change the setting displayed on
DashBoard™ and a Control Panel; a change made using DashBoard™ will similarly change the
setting displayed on a Control Panel and the card itself).