9066 Function Submenu List and Descriptions

3-48

9066 PRODUCT MANUAL

9066-OM (V4.5)

(continued)

Note:

• Although the output line drop-down on the controls described below will allow a particular range of choices, the actual

range is automatically clamped (limited) to certain ranges to prevent inadvertent conflict with active picture area
depending on video format. See Ancillary Data Line Number Locations and Ranges (p. 3-8) for more information.

• The card does not check for conflicts on a given line number. Make certain the selected line is available and carrying

no other data.

Insertion controls described below enable or disable insertion on output video only when the Scaler is enabled.

Existing waveform or packet-based data on an unscaled stream are not affected by these controls and are passed on
the SDI output.

• SD VITC Waveform Insertion Controls

For SD output, enables or disables SD VITC waveform timecode insertion
into the output video, and selects the VITC1 and VITC2 line numbers (6
thru 22) where the VITC waveform is inserted.

Note: • If only one output line is to be used, set both controls for the same

line number.

SD VITC Waveform Insertion control only affects VITC

waveforms inserted (or copied to a new line number) by this
function.

• SD ATC Insertion Control

For SD output, enables or disables SD ATC_VITC timecode insertion into
the output video, and selects the line number for ATC_VITC.

• HD ATC_LTC Insertion Control

For HD output, enables or disables ATC_LTC timecode insertion into the
output video, and selects the line number for ATC_LTC timecode data.

• HD ATC_VITC Insertion Control

For HD output, enables or disables ATC_VITC timecode insertion into the
output video, and selects the line number for ATC_VITC1 and
ATC_VITC2.

Note: If only one output line is to be used, set both controls for the same

line number.

• ATC_VITC Legacy Support Control

When enabled, accommodates equipment requiring ATC_VITC packet in
both fields as a “field 1” packet (non-toggling).

Note: Non-toggling VITC1 and VITC2 packets do not conform to

SMPTE 12M-2-2008 preferences. As such, ATC_VITC Legacy
Support should be enabled only if required by downstream
equipment.

Table 3-2

9066 Function Submenu List — continued