T89C51CC01

Rev. D – 17-Dec-01

Launch the programming by writing the data sequence 52h followed by A2h in
FCON register (only from FM1).
The end of the programming indicated by the FBUSY flag cleared.

Enable the interrupts.

Figure 13. Flash and Extra row Programming Procedure

Hardware Security Byte

The following procedure is used to program the Hardware

Security

Byte space

and is summarized in Figure 14:

Set FPS and map Hardware byte (FCON = 0x0C)

Save and disable the interrupts.

Load DPTR at address 0000h.

Load Accumulator register with the data to load.

Execute the MOVX @DPTR, A instruction.

Launch the programming by writing the data sequence 54h followed by A4h in
FCON register (only from FM1).
The end of the programming indicated by the FBusy flag cleared.

Restore the interrupts

.

FLASH Spaces

Programming

Save & Disable IT

EA= 0

Launch Programming

FCON= 5xh
FCON= Axh

End Programming

Restore IT

Column Latches Loading

see Figure 12

FBusy

Cleared?

Clear Mode

FCON = 00h