The state transition timing is calculated based on the timing of the individual blocks shown in

Figure 7-3 on page 39

to

Figure 7-7 on page 41

. The worst case values include maximum oper-

ating temperature, minimum supply voltage, and device parameter variations.

10

t

TR10

PLL_ON

BUSY_TX

16

When asserting pin 11 (SLP_TR) or TRX_CMD = TX_START
first symbol transmission is delayed by 16 µs delay (PLL
settling and PA ramp up)

11

t

TR11

BUSY_TX

PLL_ON

32

PLL settling time from TX_BUSY to PLL_ON state

12

t

TR12

All modes

TRX_OFF

1

Using TRX_CMD = FORCE_TRX_OFF (see register 0x02,
TRX_STATE),
Not valid for SLEEP state

13

t

TR13

RESET

TRX_OFF

37

Valid for P_ON or SLEEP state

14

t

TR14

Various
States

PLL_ON

1

Using TRX_CMD = FORCE_PLL_ON (see register 0x02,
TRX_STATE),
Not valid for SLEEP, P_ON, RESET, TRX_OFF and *_NO_CLK

Table 7-1.

State Transition Timing (Continued)

No

Symbol

Transition

Time [µs], (type)

Comments

Table 7-2.

Analog Block Initialization and Settling Time

No

Symbol

Block

Time [µs], (type)

Time [µs], (max)

Comment

15

t

TR15

XOSC

215

1000

Leaving SLEEP state, depends on crystal Q factor and
load capacitor

16

t

TR16

FTN

25

FTN tuning time fixed

17

t

TR17

DVREG

60

1000

Depends on external bypass capacitor at DVDD
(CB3 = 1 µF nom., 10 µF worst case), depends on V

DD

18

t

TR18

AVREG

60

1000

Depends on external bypass capacitor at AVDD
(CB1 = 1 µF nom, 10 µF worst case), depends on V

DD

19

t

TR19

PLL, initial

110

155

PLL settling time TRX_OFF

PLL_ON, including 60 µs

AVREG settling time

20

t

TR20

PLL settling

11

24

Settling time between channels switch

21

t

TR21

PLL, CF cal

35

PLL center frequency calibration, refer to

Section 9.7.4

22

t

TR22

PLL, DCU cal

6

PLL DCU calibration, refer to

Section 9.7.4

23

t

TR23

PLL, RX

TX

16

Maximum PLL settling time RX

TX

24

t

TR24

PLL, TX

RX

32

Maximum PLL settling time TX

RX

25

t

TR25

RSSI, update

2

RSSI update period in receive states, refer to

Section 8.3.2

26

t

TR26

ED

140

ED measurement period, refer to

Section 8.4.2

27

t

TR27

SHR, sync

96

Typical SHR synchronisation period, refer to

Section 8.4.2

28

t

TR28

CCA

140

CCA measurement period, refer to

Section 8.5.2

29

t

TR29

Random value

1

Random value update period, refer to

Section 11.2.1