6 test conditions – Rainbow Electronics AT89LP214 User Manual

Page 80

Advertising
background image

80

3538A–MICRO–7/06

AT89LP213/214 [Preliminary]

Figure 24-6. Shift Register Mode Timing Waveform

24.6

Test Conditions

24.6.1

AC Testing Input/Output Waveform

(1)

Note:

1. AC Inputs during testing are driven at V

CC

- 0.5V for a logic “1” and 0.45V for a logic “0”. Timing measurements are made at

V

IH

min. for a logic “1” and V

IL

max. for a logic “0”.

24.6.2

Float Waveform

(1)

Note:

1. For timing purposes, a port pin is no longer floating when a 100 mV change from load voltage occurs. A port pin begins to

float when 100 mV change from the loaded V

OH

/V

OL

level occurs.

24.5

Serial Port Timing: Shift Register Mode Test Conditions

The values in this table are valid for V

CC

= 2.4V to 5.5V and Load Capacitance = 80 pF.

Symbol

Parameter

Variable Oscillator

Units

Min

Max

t

XLXL

Serial Port Clock Cycle Time

2t

CLCL

-15

µs

t

QVXH

Output Data Setup to Clock Rising Edge

t

CLCL

-15

ns

t

XHQX

Output Data Hold after Clock Rising Edge

t

CLCL

-15

ns

t

XHDX

Input Data Hold after Clock Rising Edge

0

ns

t

XHDV

Input Data Valid to Clock Rising Edge

15

ns

0

1

2

3

4

5

6

7

VALID

VALID

VALID

VALID

VALID

VALID

VALID

VALID

CLOCK

WRITE TO SBUF

OUTPUT DATA

CLEAR RI

INPUT DATA

Advertising