B.3.9. at+btver, B.3.10. at+btmode,n, B.3.11 – SENA Parani-SD100-200 User Manual

Page 33: B.3.12. at+setesc,nn

Advertising
background image

33

B.3.9. AT+BTVER?

Response

 SD100v1.1.3
 OK

Purpose

Display device firmware version

Description

Display device firmware version

Reference

AT+BTINFO?

B.3.10. AT+BTMODE,n

Response

 OK

Purpose

Set operation mode

Parameters

n=0: MODE0 (Default)
n=1: MODE1
n=2: MODE2
n=3: MODE3

Description

When the operation status is ‘Pending’ currently, change the status to ‘Standby’ with
AT+BTCANCEL prior to this command.
To take effect the ATZ must be executed or Powercycle the unit

Reference

AT+BTINFO?

Example

AT+BTMODE,2
 OK
ATZ

B.3.11. +++

Response

 OK

Purpose

Convert the operation status of ‘Connect’ to ‘Standby’

Description

In ‘Connect’ status, data from host is transmitted to the other side Bluetooth device, and
any AT command is not accepted but this command, which is not echoed on the screen.
When Parani-SD encounters a character ‘+’ from host, it stops the data transmission and
waits for next 2 characters. If the next 2 characters aren’t both ‘+’, it restart to transmit data
including the first ‘+’ as well. If not, it converts the operation status to ‘Standby’.
If the data from host includes ‘+++’, it will convert the operation status to ‘Standby’. Notice
that Parani-SD holds data transmission when it encounters ‘+’, until receiving next
character.
‘+’ is an escape sequence character by default, which is changeable by AT+SETESC.

Reference

AT+SETESC, ATO, AT+BTCANCEL

B.3.12. AT+SETESC,nn

Response

 OK

Purpose

Change the escape sequence character

Description

Escape sequence character set to ‘+’ by default is changeable.
The parameter nn must be a printable character.