B.4. command validity, B.3.31. at&v, B.3.32. atsnn – SENA Parani-SD100-200 User Manual
Page 39: B.3.33. atsnn=mm
39
B.3.31. AT&V
Response
S0:m0;S1:m1; …Sn:mn
OK
Purpose
Display all the S-registers
Description
All parameters are stored at S-register in flash memory. These values are sustained until a
hardware reset.
Reference
ATS
B.3.32. ATSnn?
Response
value
OK
Purpose
Display a given S-register
Parameters
nn= Address of S-register
Description
A specific S-register will be displayed.
Reference
AT&V
B.3.33. ATSnn=mm
Response
OK
Purpose
Change S-register value
Parameters
nn= Address of S-register
mm= New value of S-register
Description
Some S-registers are optimized for the overall performance and protected and cannot be
changed. When users try to change these S-registers, response is ‘ERROR’.
For details of S-register, refer Appendix. B.
Reference
AT&V
Example
ATS10=0
B.4. Command Validity
Operation Status
AT Command
Standby
Pending
Connect
AT
○
○
ATZ
○
○
AT&F
○
○
AT+BINQ?
◎
ATD112233445566
◎