4.1.2 TCP Server Mode Configuration

To configure the NEMO10 to work as a TCP server, use ‘set’ command as follows:

set host tcps listening_TCP_port inactivity_timeout + <CR>

where,

listening_TCP_port: Listening TCP port

Inactivity_timeout: Inactivity timeout in seconds.

Listening TCP port is the TCP port number through which remote host can connect a TCP session,

and, send and receive data. Incoming connection request to the ports other than Listening TCP Port

will be rejected. The NEMO10 does not restrict the number to a specific range, but it is strongly

recommended not to use the well-known ports for certain application (See Appendix B: Well-known

Port Numbers). To change the port number, select menu 2 on the TCP Server mode configuration

screen.

Inactivity timeout is set to maintain the TCP connection state as Closed or Listen in TCP host mode

unless there is any data transfer between the serial device and the NEMO10. If there is no incoming or

outgoing data through the serial port during the specified inactivity timeout interval, the existing TCP

connection will be closed automatically.

If the value of inactivity timeout is set to 0, the current TCP connection is maintained unless there’s no

connection close request. Although inactivity timeout is disabled, the NEMO10 will check the

connection status between the NEMO10 and the remote host by sending “keep alive” packets

periodically. If the remote host does not answer the packets, it is regarded that the connection is down

unintentionally. Then, the NEMO10 will force to close the existing TCP connection.

Note: At least, this value should be set larger than that of inter-character timeout. To prevent the

unintended loss of data due to the session disconnection, it is highly recommended that this value is

set large enough so that the intended data transfer is completed.

Figure 4-2 shows TCP server mode setting example:

> set host tcps 6001 300
OK
>

Figure 4-2 TCP server mode setting