2 lamp data, 1 geometric data, 1 osram dulux® s – OSRAM DULUX F User Manual

Page 26: 2 osram dulux® s/e, Lamp data, 1 osram dulux, 2 osram dulux

Advertising
background image

Economical long-life light sources with plug-in bases

Compact Fluorescent Lamps OSRAM DULUX

®

Technical Guide

24

2 Lamp data

2.1 Geometric data

Single capped lamp geometry is defined by parameters giving the diameter and the length of the
lamp. For lamp length two parameters are important to know. There is an overall length which de-
scribes the total distance from the very beginning to the end of the lamp and which is called „Over-
all length“ in this document. Sometimes it might be also called “rated overall length”. This length is
important to know to allow enough free space for lamp insertion and withdrawal in a luminaire. It
might include the length of pins if they surmount the lower lamp end or the length of a cap guide
post. The second parameter corresponds to the maximum length as it is given in IEC which lasts
from the lamp cap reference plane to the lamp top. This is called “maximum length” in this docu-
ment. Sometimes it might be called “rated length” in technical specifications. This dimension de-
scribes the length of the lamp which is visible if the lamp is inserted in the holder.

2.1.1 OSRAM DULUX

®

S

Type

Maximum length

1)

L1

mm

Maximum length

1)

L2

mm

Maximum length L1 IEC
mm

Base

OSRAM DULUX

®

S 5 W

85

108

85

G 23

OSRAM DULUX

®

S 7 W

114

137

115

G 23

OSRAM DULUX

®

S 9 W

144

167

145

G 23

OSRAM DULUX

®

S 11 W

214

237

215

G 23

1) -4mm tolerance
Base – IEC/EN60061-1, Sheet 7004-69

2.1.2 OSRAM DULUX

®

S/E

Type

Maximum length

1)

L1

mm

Maximum length L1 IEC
mm

Maximum length L2

mm

Base

OSRAM DULUX

®

S/E 7 W

114

115

119

2G7

OSRAM DULUX

®

S/E 9 W

144

145

149

2G7

OSRAM DULUX

®

S/E 11 W

214

215

219

2G7

1)

-4 mm tolerance

Base – IEC/EN60061-1, Sheet 7004-102

L

1

L

2

Advertising