Economical long-life light sources with plug-in bases

Compact Fluorescent Lamps OSRAM DULUX

®

Technical Guide

58

heats up and releases mercury into the discharge. This behaviour can be especially observed under
lower temperatures.

Therefore in CONSTANT lamps an additional run-up amalgam is positioned in the direct neighbour-
hood of the electrode. After the lamp is switched on, the electrode will heat up the flag containing
the run-up amalgam, so that mercury is directly released into the discharge. This results in a quick
run-up behaviour of the CONSTANT lamp that is nearly identical to a Cold Spot lamp.

Once all the mercury from the run-up amalgam is released, the operation amalgam will take over the
Hg vapour pressure control, until its final stabilization (until the light output is stabilized).

Typical run-up behaviour of OSRAM DULUX® T/E CONSTANT (amalgam lamps) in ECG operation, 25 ºC
ambient temperature, mains voltage 230 V/ 50 Hz, free-operating