Maximum cap temperature, lamps with internal or external starter (test at abnormal operating
conditions)

Lamp

Lamp nominal wattage

Maximum cap temperature

°C

DULUX

®

F

All

200

CFL SQUARE

®

2, 4 pin

All

110 *

DULUX

®

L (XT, CONSTANT)

18, 24, 36

200

DULUX

®

S

All

200

DULUX

®

D, D/E (XT), D ES

All

200

DULUX

®

T, T/E (CONSTANT)

13, 18, 24

200

* Under consideration.

If a magnetic ballast with (short-circuited) internal or external starter is used, the luminaire designer
should ensure that the cap temperature of the lamp, under abnormal operating conditions, does not
exceed the maximum cap temperature value shown in the table above.

Luminaires should be tested using the intended lamp with the starter short-circuited (test at
abnormal operating conditions), i.e. the cathodes operated in series.

Maximum cap temperature, lamps for ECG operation (test at normal operating conditions)

Lamp

Lamp nominal wattage

[W]

Maximum cap temperature

[°C]

DULUX

®

S/E, DULUX

®

F, DULUX

®

L (CONSTANT, HE, SP, XT)

All

180

CFL SQUARE

®

4 pin

All

100*

DULUX

®

D/E, T/E (CONSTANT, HE, XT)

All

180

* Under consideration

If a high frequency ballast is used, the luminaire designer should ensure that the cap temperature of
the lamp under normal operating conditions does not exceed the maximum temperature value
shown in the table above.