Compact Fluorescent Lamps OSRAM DULUX

®

Technical Guide

78

Lamp

P [W]

Q [J]

Rsub [

Ω]

min

max

min

max

min

max

OSRAM DULUX

®

S/E 7 W

0.5

1.0

1.0

2.0

30

40

OSRAM DULUX

®

S/E 9 W

0.5

1.0

1.0

2.0

30

40

OSRAM DULUX

®

S/E 11 W

0.5

1.0

1.0

2.0

30

40

OSRAM DULUX

®

D/E 10 W

0.6

1.2

1.0

2.0

30

40

OSRAM DULUX

®

D/E 13 W

0.7

1.4

1.0

2.0

30

40

OSRAM DULUX

®

D/E 18 W

3)

0.7

1.4

0.9

1.8

18

24

OSRAM DULUX

®

D/E 26 W

3)

0.8

1.6

1.0

2.0

9

12

OSRAM DULUX

®

T/E 13 W

0.7

1.4

1.0

2.0

30

40

OSRAM DULUX

®

T/E 18 W

0.7

1.4

0.9

1.8

18

24

OSRAM DULUX

®

T/E 26 W

1)

0.8

1.6

1.0

2.0

9

12

OSRAM DULUX

®

T/E 32 W

1) 3)

0.8

1.6

1.0

2.0

9

12

OSRAM DULUX

®

T/E 42 W

1)

3)

0.8

1.6

1.0

2.0

9

12

OSRAM DULUX

®

T/E 11W HE

0.7

1.4

1.0

2.0

30

40

OSRAM DULUX

®

T/E 14W HE

0.7

1.4

1.0

2.0

30

40

OSRAM DULUX

®

T/E 17W HE

0.7

1.4

1.0

2.0

30

40

OSRAM DULUX

®

L 18 W

3)

0.9

1.8

1.5

3.0

8

11

OSRAM DULUX

®

L 24 W

3)

0.9

1.8

1.5

3.0

8

11

OSRAM DULUX

®

L 36 W

3)

1.0

2.0

1.6

3.2

7

9

OSRAM DULUX

®

L 40 W

1)

0.9

1.8

1.5

3.0

8

11

OSRAM DULUX

®

L 55 W

1)

3)

1.1

2.2

2.4

4.8

5

6.5

OSRAM DULUX

®

L 80 W

1)

1.5

3.0

2.4

4.8

5

6.5

OSRAM DULUX

®

L 16 W HE

0.75

1.5

0.9

1.8

30

45

OSRAM DULUX

®

L 22 W HE

0.75

1.5

0.9

1.8

30

45

OSRAM DULUX

®

L 26 W HE

0.75

1.5

0.9

1.8

30

45

OSRAM DULUX

®

L 28 W HE

0.75

1.5

0.9

1.8

30

45

OSRAM DULUX

®

F 18 W

0.9

1.8

1.5

3.0

8

11

OSRAM DULUX

®

F 24 W

0.9

1.8

1.5

3.0

8

11

OSRAM DULUX

®

F 36 W

1.0

2.0

1.6

3.2

7

9

CFL SQUARE

®

16W

2)

0.6

1.2

0.9

1.8

40

50

CFL SQUARE

®

28W

2)

0.9

1.8

1.1

2.2

12

16

CFL SQUARE

®

38W

2)

1.0

2.0

2.0

4.0

5.6

8.2

1) Also for DULUX

®

CONSTANT

2) CFL SQUARE

®®

four-pin base

3) also for XT versions

5.1.2 Starting (ECG operation)

The lamp should not ignite during the preheating time; the open-circuit voltage of the ECG must
therefore not exceed a lamp-specific maximum value. After the preheating phase the lamp should
ignite reliably; the open-circuit voltage of the ECG must therefore not fall below a lamp-specific
minimum value. The following table contains the permissible or necessary limit values for the open-
circuit voltage of the ECG. Because of the temperature response of the ignition voltage of
fluorescent lamps and compact fluorescent lamps, these values are given for two ambient
temperature ranges.