Dimming means reducing wattage to save energy.
The following values emerge per DIM level, lamp type
and wattage for each system.

Light and wattage details for a PTo 50 3DIM system

PTo 50 3DIM

HCI-TT 50W WDL

NAV-T 50W Super

DIM-Level
[%]

PL
[W]

PS
[W]

PHI
[lm]

ETA
[lm/W]

ETA sys
[lm/W]

CT
[K]

Ra

PHI
[lm]

ETA
[lm/W]

ETA sys
[lm/W]

100

50.5

56.4

4960

98.1

87.9

3041

79

4005

79.3

71.0

90

45.7

51.2

4375

95.7

85.5

3183

75

3380

73.9

66.0

80

40.6

45.6

3725

91.8

81.7

3389

71

2715

66.8

59.5

75

37.9

42.7

3375

89.1

79.0

3521

69

2380

62.7

55.7

70

36.0

40.6

3115

86.6

76.7

3634

67

2140

59.4

52.7

60

33.6

38.1

Not released, dimming to 60 %

1890

56.3

49.6

Light and wattage details for a PTo 70 3DIM system

PTo 70 3DIM

HCI-TT 70W WDL

NAV-T 70W Super

DIM-Level
[%]

PL
[W]

PS
[W]

PHI
[lm]

ETA
[lm/W]

ETA sys
[lm/W]

CT
[K]

Ra

PHI
[lm]

ETA
[lm/W]

ETA sys
[lm/W]

100

73.3

80.9

7150

97.5

88.4

3003

89

6810

92.9

84.2

90

64.5

71.4

6280

97.4

88.0

3056

84

5675

88.0

79.5

80

56.6

62.8

5435

96.1

86.5

3141

80

4595

81.2

73.1

75

51.8

57.8

4890

94.4

84.7

3225

78

3940

76.0

68.2

70

47.8

53.4

4430

92.7

82.9

3322

75

3400

71.2

63.7

60

46.1

51.8

4175

90.5

80.6

3439

73

3150

68.3

60.8