Tender documents – OSRAM QUICKTRONIC-M ECG for circular FL 16 mm User Manual

Page 88

Advertising
background image

87

10. Tender Documents

See

www.osram.com/ecg/tender-documents

10.1 QUICKTRONIC

®

INTELLIGENT QTi

µProzessor controlled ECG to operate T5/

∅ 16 mm fluorescent lamps

FQ

®

...HO and FH

®

...HE in equal length.

Automatic lamp detection during lamp starting
Optimized Operation of all approved lamps with rated data
Lamp operation acc. to EN 60929 and IEC 60929

Range :
QTi 1x35/49/80
QTi 1x28/54

Geometry: 360 x 30 x 21 mm³

QTi 1x14/24/21/39

QTi 2x35/49
QTi 2x28/54

Geometry: 423 x 30 x 21 mm³

QTi 2x14/24/21/39

Lamp Preheat Start within 1 Second
Ambient Temperature: -20 °C up to+50 °C
Emergency Lighting acc. to . DIN VDE 0108 (EN 61347-2-3) possible

DC Voltage Range: 154 V to 276 V

AC Voltage Range:: 198 V to 254 V


Approval Marks:

- Circuitry


Automatic restart after lamp replacement
ECG-lifetime: 50.000 h with a max. 10 % failure rate (at tc = 70 °C)

10.2 QUICKTRONIC

®

MULTIWATT for
FH…HE
h = 30 mm

Fully electronical, digital control gear to operate all FH

®

...HE-fluorescent

lamps
Lamp preheat start within 1 Second
Combi Wiring Terminal for automatic and manual wiring

- Circuitry

Ambient Temperature: -20 °C to +50 °C

Emergency lighting acc. to. DIN VDE 0108 (EN 61347-2-3) possible

DC Voltage Range: 154 V to 276 V

AC Voltage Range: 198 V to 254 V

Range:
QUICKTRONIC

®

MULTIWATT

-Circuitry

-Circuitry

Advertising