Option b (pg 11), Modified, Mil-prf-55310 – Q-Tech CLASS B+ User Manual

Page 11: Level b, See details in, Table iii, Q-tech, Class b+ products

Advertising
background image

Q-TECH Corporation - 10150 W. Jefferson Boulevard, Culver City 90232 - Tel: 310-836-7900 - Fax: 310-836-2157 - www.q-tech.com

11 of 27

Q-TECH

CORPORATION

QPDS-0001, Rev L, June 2013 (ECO #10851)

CLASS B+ PRODUCTS

HIGH RELIABILITY HYBRID CRYSTAL CLOCK OSCILLATORS

2.5 to 5.0Vdc - 15kHz to 350MHz

Test Description

MIL

Standard Method Condition Qty

Comments

Internal Visual

883

2017

Class H

100%

Stabilization Bake

883

1008

C

100%

48 hours at +150°C

Temperature Cycling

883

1010

B

100%

10 cycles

Constant Acceleration

883

2001

A

100%

Y1 direction only (5,000g’s)

Particle Impact Noise Detection (PIND)

883

2020

B

100%

5 passes minimum

(see Note 1)

Pre Burn-In Electrical

Refer to Table III-a and Detail Specification

100%

Burn-In

883

1015

+125°C

for 160 hours

100%

With load and nominal supply voltage

Final Electrical

Refer to Table III-a and Detail Specification

100%

Percent Defective Allowance (PDA)

38534

PDA=2% (Supply Current only)

Seal Fine Leak

883

1014

A1

100%

Seal Gross Leak

883

1014

C

100%

External Visual

883

2009

100%

Screening - Option B (Modified MIL-PRF-55310, Level B)

(Example: QT178LD10B-50.000MHz)

NOTES:

1. PIND testing shall be performed using five (5) independent passes and all failures found at the end of each pass are rejected. The

survivors of the last pass are acceptable.

2. 100% Group A QCI test per MIL-PRF-55310

Parameters

Pre BI

at 25ºC

Pre BI

Low Temp

Pre BI

High Temp

Post BI

at 25ºC

Post BI

Low Temp

Post BI

High Temp

Output frequency

Frequency/temperature stability

Frequency/voltage stability

Input current

Output voltage

Waveform

Duty cycle

Rise and fall times

Start up time

Tristate Function (if applicable)

Table III-a

Electrical Test - Measurement Requirements

QCI (per MIL-PRF-55310, Level B or S) (To be specified on Purchase Order)

• Group B (AgingTest)
• Group C (See details on Table VIII)

QCI Options (per MIL-PRF-38534, Class K-Modified)

• Group B Inspection per MIL-PRF-38534, Class K-Modified (See details on Table V)
• Group C Inspection per MIL-PRF-38534, Class K-Modified (Delta Limits per Table II) (See details on Table VI)
• Group D Inspection per MIL-PRF-38534, Class K-Modified (See details on Table VII)

Table III

Back To Summary

Advertising