Operating Manual VH Series 700 - 1000 -1500 – 2000 VA UL

5

COMMUNICATION

5.1 USB PORT

The USB port is a plug-in interface port which enables advanced communication between the UPS and the computer (UPS
software required). The interface port is operative as soon as the mains power cord is plugged into a live wall outlet, even if
the UPS is switched off.
For more information please refer to the user manual that comes with the interface software. We strongly recommend to
use only original GE Digital Energy software products in combination with the interface port.

NOTE

The change of some settings can cause the unit to switch from bypass to standby and output power is lost.


5.2

RJ11 PORT

The RJ11 port is a plug-in contact interface port.

Pin #

Function

1

Mains failure

2

General alarm

*)

3

Battery low

4

On bypass

5

Remote UPS shutdown / RxD

6

GND

*) Active if the output voltage of the UPS is no longer

guaranteed due to other circumstances than already
indicated by pin 1-3-4. The alarms are listed in section 4.4.9.

Fig. 5.2

Absolute Maximum Ratings

MIN

MAX

V

O

Voltage applied on any output pin

-0.2V

48V

I

O

Output sink current

30mA

V

I

Voltage applied on input pin

-25V

25V

Note: Exceeding these ratings may damage the device or anyway affect its reliability

DC Characteristics

CONDITION

MIN

MAX

V

IH

High-level input voltage

4.0V

V

IL

Low-level input voltage

0.4V

V

OL

Low (active) output voltage

Io<1mA

0.4V


5.3 USB / RS232 / RELAY INTERFACE CARD (OPTION)

The card is equipped with
• USB port as described in 5.1
• RS232 port
• potential free change-over relay contacts for the following alarms:

- mains failure

- general alarm

- battery low

- bypass active

For more information please refer to the user manual that comes with the interface card.

5.4 SNMP / WEB INTERFACE CARD (OPTION)

The SNMP card makes the UPS ‘SNMP manageable’: it allows the data interface to be connected directly to an Ethernet
network. For more information please refer to the user manual that comes with the interface card.