Measuring the Temperature using the PMBus

The module can provide temperature information using the

READ_TEMPERATURE_1 command. The command returns
two bytes of data in the linear format. The upper five bits

[7:3] of the high data byte form the two’s complement
representation of the exponent, which is fixed at –2 (decimal).
The remaining 11 bits are used for two’s complement

representation of the mantissa.

Note that the module’s temperature sensor is located close
to the module hot spot TH

1

(see Thermal Considerations).and

is subjected to temperatures higher than the ambient air
temperature near the module. The temperature reading will

be highly influenced by module load and airflow conditions.

Reading the Status of the Module using the PMBus

The module supports a number of status information

commands implemented in PMBus. However, not all features
are supported in these commands. A X in the FLAG cell
indicates the bit is not supported.

STATUS_WORD : Returns two bytes of information with a
summary of the module’s fault/warning conditions.

High Byte

Bit Position

Flag

Default Value

15 VOUT

fault

0

14

IOUT fault or warning

0

13

Input Voltage fault

0

12 X

0

11

POWER_GOOD# (is negated)

0

10 X

0

9 X 0
8 X 0

Low Byte

Bit Position

Flag

Default Value

7 X 0
6 OFF 0
5 VOUT

Overvoltage 0

4 IOUT

Overcurrent 0

3 VIN

Undervoltage 0

2 Temperature 0
1

CML (Comm. Memory Fault)

0

0 X 0


STATUS_VOUT : Returns one byte of information relating to
the status of the module’s output voltage related faults.

Bit Position

Flag

Default Value

7

VOUT OV Fault

0

6 X 0
5 X 0
4 X 0
3 X 0
2 X 0
1 X 0
0 X 0




STATUS_IOUT : Returns one byte of information relating to

the status of the module’s output current related faults.

Bit Position

Flag

Default Value

7

IOUT OC Fault

0

6 X 0
5

IOUT OC Warning

0

4 X 0
3 X 0
2 X 0
1 X 0
0 X 0

STATUS_INPUT : Returns one byte of information relating to
the status of the module’s input voltage related faults.

Bit Position

Flag

Default Value

7

VIN OV Fault

0

6 X 0
5 X 0
4

VIN UV Fault

0

3

Module Off (Low VIN)

0

2 X 0
1 X 0
0 X 0

STATUS_TEMPERATURE : Returns one byte of information

relating to the status of the module’s temperature related
faults.

Bit Position

Flag

Default Value

7 OT

Fault 0

6 OT

Warning 0

5 X 0
4

X 0

3 X 0
2 X 0
1 X 0
0 X 0

STATUS_CML : Returns one byte of information relating to the
status of the module’s communication related faults.

Bit Position

Flag

Default Value

7

Invalid/Unsupported

Command

0

6 Invalid/Unsupported

Data 0

5

Packet Error Check Failed

0

4 X 0
3 X 0
2 X 0
1 X 0
0 X 0