Feature Specifications

Unless otherwise indicated, specifications apply over all operating input voltage, resistive load, and temperature conditions. See
Feature Descriptions for additional information.

Parameter

Device

Symbol

Min

Typ

Max

Unit

Remote On/Off Signal Interface

(V

IN

=V

IN, min

to V

IN, max

, Signal referenced to V

IN-

terminal)

Negative Logic: device code suffix “1”
Logic Low = module On, Logic High = module Off

Positive Logic: No device code suffix required
Logic Low = module Off, Logic High = module On

On/Off Thresholds:

Remote On/Off Current – Logic Low (Vin =100V)

All

I

on/off

280

310

μA

Logic Low Voltage

All

V

on/off

-0.3

0.8 V

dc

Logic High Voltage – (Typ = Open Collector)

All

V

on/off

2.0

14.5 V

dc

Logic High maximum allowable leakage current

(V

on/off

= 2.0V)

All I

on/off

10

μA

Maximum voltage allowed on On/Off pin

All

V

on/off

14.5 V

dc

TON_DELAY and TON_RISE (I

O

=I

O, max

)

(Adjustable via PMBus)

T

delay

=Time until V

O

= 10% of V

O,set

from either application of Vin

with Remote On/Off set to On (Enable with Vin); or operation of

Remote On/Off from Off to On with Vin already applied for at

least 150 milli-seconds (Enable with on/off).
* Increased T

delay

due to startup for parallel modules.

All w/o -P T

delay, Enable with Vin

160 ms

All w/o-P

T

delay, Enable with

on/off

40 ms

w/ -P

T

delay

,

Enable with Vin

180* ms

w/ -P

T

delay, Enable with

on/off

40* ms

T

rise

=Time for V

O

to rise from 10% to 90% of V

O,set

, For C

O

>5000uF, I

O

must be < 50% I

O, max

during T

rise

.

* Increased T

rise

when Vo exists at startup for parallel

modules.

All w/o -P

T

rise

40 ms

w/ -P

T

rise

300* ms

Load Sharing Current Balance
(difference in output current across all modules with outputs in
parallel, no load to full load)

-P Option

I

diff

3 A

Remote Sense Range

All

V

Sense

0.5 V

dc

External Resistor Trim Range

All

V

O, set

6.0

13.2 V

dc

VOUT_COMMAND
(Adjustable via PMBus)

All V

O, set

5.0

13.2 V

dc

VOUT_OV_FAULT_LIMIT
(Adjustable via PMBus)

All V

O,limit

15 V

dc

OT_FAULT_LIMIT
(Adjustable via PMBus)

All T

ref

140

°C

Input Undervoltage Lockout

(Adjustable via PMBus)

VIN_ON

34 35 36 V

dc

VIN_OFF

32 33.5 34.5 V

dc

Input Overvoltage Lockout
(Adjustable via PMBus)
Turn-off Threshold [VIN_OV_FAULT_LIMIT]

85

V

dc

Turn-on Threshold
(follows VIN_OV_FAULT_LIMIT -7V)

79

V

dc

Pull down resistance of Power Good pin
Sink current capability into Power Good pin (V

PG

=2.2V)

All
All

150

15

mA

Advertising