Data sheet – GE Industrial Solutions EBDW020A0B Barracuda Series User Manual

Page 5

Advertising
background image

GE

Data Sheet

EBDW020A0B Barracuda™ Series; DC-DC Converter Power Modules

36-75Vdc Input; 12.0Vdc, 20.0A, 240W Output

April 15, 2013

©2012 General Electric Company. All rights reserved.

Page 5

General Specifications

Digital Interface Specifications

Unless otherwise indicated, specifications apply over all operating input voltage, resistive load, and temperature conditions. See
Feature Descriptions for additional information.

Parameter

Conditions

Symbol

Min

Typ

Max

Unit

PMBus Signal Interface Characteristics
Input High Voltage (CLK, DATA)

V

IH

2.1 3.6

V

Input Low Voltage (CLK, DATA)

V

IL

0.8

V

Input high level current (CLK, DATA)

I

IH

-10 10

μA

Input low level current (CLK, DATA)

I

IL

-10 10

μA

Output Low Voltage (CLK, DATA, SMBALERT#)

I

OUT

=2mA V

OL

0.4

V

Output high level open drain leakage current (DATA,
SMBALERT#)

V

OUT

=3.6V I

OH

0 10

μA

Pin capacitance

C

O

0.7

pF

PMBus Operating frequency range
(* 5-10 kHz to accommodate hosts not supporting clock
stretching)

Slave Mode

F

PMB

5* 400

kHz

Measurement System Characteristics

Output current reading range

I

OUT(RNG)

0.56

63.9375

A

Output current reading resolution

I

OUT(RES)

0.19 A

Output current reading accuracy

5A < Iout <20A

I

OUT(ACC)

-5.0 4.0 %

Output current reading accuracy (absolute difference
between actual and reported values)

0.56A < Iout <5A

I

OUT(ACC)

-1.4 2.7 A

V

OUT

reading range

V

OUT(RNG)

0

15.9997

V

V

OUT

reading resolution

V

OUT(RES)

0.244 mV

V

OUT

reading accuracy

V

OUT(ACC)

-2.0 0.6 2.0 %

V

IN

reading range

V

IN(RNG)

0

127.875

V

V

IN

reading resolution

V

IN(RES)

125 mV

V

IN

reading accuracy

V

IN(ACC)

-4.0 0.8 4.0 %

Temperature reading resolution

T

(RES)

0.25

°C

Temperature reading accuracy

T

(ACC)

-5.0 5.0 %

Parameter

Device

Symbol

Typ

Unit

Calculated Reliability Based upon Telcordia SR-332 Issue
2: Method I, Case 3, (I

O

=80%I

O, max

, T

A

=40°C, Airflow = 200

LFM), 90% confidence

All MTBF

4,169,213

Hours

All FIT

239.9 10

9

/Hours

Weight – Open Frame

30.0 (1.06)

g (oz.)

Weight – with Base plate option

39.5 (1.39)

g (oz.)

Advertising