Frame assembly wiring harness installation, Installing, Insulating barrier – GE Industrial Solutions ProTrip Conversion Kits AK-1-50 User Manual

Page 11: Wiring harness connection to the cts, Adjusting the flux shifter

Advertising
background image

Adjusting the Flux Shifter

With the breaker in the CLOSED position, the gap
between the adjustment screw and the trip paddle should
be

1

/

16

inch, as shown in Figure 15. For safety, OPEN

the breaker to adjust the screw with a

1

/

4

-inch wrench.

WARNING: Be extremely careful when working on a
closed breaker. Do not reach into the mechanism while
adjusting the flux shifter.

Optional Test – The flux shifter may be tested by closing
the breaker and applying a 9 Vdc power source to the
flux shifter leads (the red wire is positive). The breaker
should trip.

Figure 15. Adjusting the flux shifter.

11

Advertising